November 01 (Wednesday)
냉동 및 저온공학
Oral,
제5발표장(203호),
15:50~16:50
  • Chair :
  •  이영림(공주대)
We05C-1
15:50~16:50
1D-CFD 연계 모델을 이용한 냉매 압축기 과열도 예측
황일선(공주대학교 천안공과대학), 이영림(공주대학교 기계자동차공학부)
The refrigerant temperature inside a conventional compressor was mainly predicted by using the 1D (one-dimensional) lumped model. However, more accurate temperature prediction has been available by the recent introduction of 1D lumped-CFD (Computational fluid dynamics) coupled model. Therefore, in this study, we used the 1D lumped-CFD coupled model to accurately predict the refrigerant superheat of a linear compressor. The results showed that the refrigerant temperature increases through the intake system of the compressor, causing an additional superheat of about 12 °C. Since too much superheat reduces the efficiency of the refrigeration cycle, it should be optimized.
Keywords : Refrigerant compressor(냉매 압축기), 1D lumped model(1D 집중모델), superheat(과열도), suction system temperature(흡입계 온도)
Paper : We05C-1.pdf

(사)대한기계학회, 서울시 강남구 테헤란로 7길 22 한국과학기술회관 신관 702호, Tel: (02)501-3646~3648, E-mail: ksme@ksme.or.kr