November 01 (Wednesday)
열기기 및 열교환기(I)
Oral,
제4발표장(201B호),
15:50~16:50
  • Chair :
  •  백영진(KIER)
We04C-2
15:50~16:50
비대칭 출력 IGBT 설치 위치에 따른 사각 히트 싱크 방열 성능
박승재, 변성준, 정해준, 현승환, 이관수(한양대학교)
The aim of this study was to improve the thermal performance of a plate heat sink by decreasing the maximum temperature of the insulated-gate bipolar transistors (IGBTs). We investigated the effect of varying the installation method, location, and configuration of six asymmetric high- and low-power IGBTs and calculated the thermal performance of the heat sink as the IGBTs were moved. The forced convective heat transfer at the heat sink was simulated using a shear stress transport k-w turbulence model. We successfully minimized the maximum IGBT temperature by optimizing the IGBT installation location.
Keywords : Heat sink(히트싱크), Partial heating(부분히팅), IGBT(절연게이트양극성트랜지스터), Forced convection(강제대류)
Paper : We04C-2.pdf

(사)대한기계학회, 서울시 강남구 테헤란로 7길 22 한국과학기술회관 신관 702호, Tel: (02)501-3646~3648, E-mail: ksme@ksme.or.kr