November 02 (Thursday)
열기기 및 열교환기(IV)
Oral,
제3발표장(202A호),
11:00~12:00
  • Chair :
  •  김민성(부산대)
Th03C-3
11:00~12:00
2종 1단 흡수식 히트 펌프의 폐온수 공급 방법에 따른 성능 특성 실험적/해석적 비교 연구
이창현, 김병련, 손성필, 김재인, 김영진, 동월월, 서양, 호세인, 박찬우(전북대학교)
This study was compared of numerical analysis that effects of waste hot water supply order on the performance of type II absorption heat pump. There are two kind of waste hot water supply order, regular series flow and reverse series flow. In the regular and reverse series flow, it was investigated that interaction of between the temperature of hot waste water with a heat exchanger. In the certain effectiveness of solution heat exchanger, As the temperature increse, the steam generation and COP increases. Thus, the higher temperature of hot waste water in the Type II absorption heat pump, the more steam generation rate and COP can be obtainded.
Keywords : Absorption Heat Pump(흡수식 히트펌프), COP(성적계수), H2O/LiBr(물/리튬브로마이드), Hot Waste Water(폐온수), Heat Transfomer(히트트렌스포머)
Paper : Th03C-3.pdf