November 03 (Friday)
구조설계 및 CAE(X)
Oral,
제15발표장(402B호),
13:00~14:00
  • Chair :
  •  노유정(부산대)
Fr15D-1
13:00~14:00
고압차단기 주조용 AC4CH-T6 합금 외함 파열압력 예측
이희태(현대일렉트릭), Ma Ning, Wang Li(현대중공업)
The gas insulated switchdear(GIS) is a mechanical switching device that connects and breaks current circuit to protect the electric equipment in a power network. To maintain the highest insulation level, main parts of the GIS were placed in the tank with insulating gas under the prescribed design pressure. According to IEC62271-203, it is necessary that tank should have strength to endure the pressure of the proof test which reaches many times of the design pressure to consider rapid increase of the internal pressure and the possible valiability of manufacturing process of the tank. For this reason, it is very important to predict the burst pressure of the tank to design the AC4CH-T6 casting aluminum alloy tank of GIS appropriately. In this study, a fracture criterion was proposed to predict tha fracture response of the AC4CH-T6 casting aluminum alloy by conducting a series of tests. By using the fracture criterion of the AC4CH-T6 and Finite Element Analysis(FEA), the burst pressure of actual tanks was proposed. Finally, the validity of predicted burst pressure of the tank was evaluated by compaing results from the actual hydaulic test of the tank.
Keywords : Cast aluminum alloy(주조용 알루미늄 합금), Burst pressure(파열압력), Ductile Fracture(연성파괴), Stress triaxiality(삼축응력), Fracture Strain(파괴변형률)
Paper : Fr15D-1.pdf